{"id":84,"date":"2017-09-29T22:27:54","date_gmt":"2017-09-30T05:27:54","guid":{"rendered":"http:\/\/chem.wsu.edu\/guo\/?page_id=84"},"modified":"2019-09-25T13:50:24","modified_gmt":"2019-09-25T20:50:24","slug":"capabilities","status":"publish","type":"page","link":"https:\/\/chem.wsu.edu\/guo\/capabilities\/","title":{"rendered":"Capabilities"},"content":{"rendered":"<br \/>\n<section id=\"builder-section-1546707620287\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<h4>Laboratory:<\/h4>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1546393935269\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-188\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-792x232.jpg\" alt=\"\" width=\"792\" height=\"232\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-792x232.jpg 792w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-396x116.jpg 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-768x225.jpg 768w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-990x290.jpg 990w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-1188x347.jpg 1188w\" sizes=\"(max-width: 792px) 100vw, 792px\" \/><br \/>\nThe Guo Labs are fully equipped with unique high-temperature calorimetry instruments, high-pressure apparatus, and a complete synthesis capability for material preparation.<\/p>\n<hr \/><\/div>\n<\/section>\n<section id=\"builder-section-1546399764664\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<h4>Equipment:<\/h4>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1546710474098\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p><span style=\"color: #8b2a35\"><strong><u>High-Temperature Calorimeters:<\/u><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-134\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/Alexsys-396x311.png\" alt=\"\" width=\"350\" height=\"275\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/Alexsys-396x311.png 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/Alexsys.png 483w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/p>\n<p>Setaram AlexSYS-1000 Calvet-type calorimeter for solution and reaction calorimetry at 500 to 1000 \u00b0C<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-138\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/Setsys1.png\" alt=\"\" width=\"172\" height=\"215\" \/> <img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-139\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/Setsys2.png\" alt=\"\" width=\"172\" height=\"215\" \/><\/p>\n<p>Setaram SetSYS-2400 calorimeter for heats of reaction, heat capacity measurement, thermogravimetry and thermal mechanical analysis from RT to 1500 \u00b0C (Differential Scanning Calorimetry) and to 2400 \u00b0C (Differential Thermal Analysis)<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #8b2a35\"><strong><u>High-Pressure Apparatus:<\/u><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/dac3.png\" alt=\"\" width=\"172\" height=\"201.8\" \/><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\" wp-image-142 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/dac2.png\" alt=\"\" width=\"163\" height=\"102.13\" \/><img decoding=\"async\" loading=\"lazy\" class=\"alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/dac1-396x206.png\" alt=\"\" width=\"199.2\" height=\"102.13\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Diamond Anvil Cells (pressure: &lt; 50 GPa)<\/p>\n<p>Hydrothermal DAC (P-T: &lt;10 GPa, &lt;800 \u02daC)<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #8b2a35\"><strong><u>Mechanical Measurements Apparatus:<\/u><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-155 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/RUS.png\" alt=\"\" width=\"172\" height=\"212\" \/><\/p>\n<p>ACE RUS008 Resonant Ultrasound Spectrometer for determining elastic properties<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #8b2a35\"><strong><u>Material Synthesis and Characterization:<\/u><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-167 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/furnace.png\" alt=\"\" width=\"201\" height=\"201\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/furnace.png 287w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/furnace-198x198.png 198w\" sizes=\"(max-width: 201px) 100vw, 201px\" \/><\/p>\n<p>High temperature Nabertherm tube furnace (1300 \u00b0C, inert gas condition)<\/p>\n<p>High temperature Carbolite furnace (1200 \u00b0C)<\/p>\n<p>Schlenk line integrated air sensitive synthesis systems (<em>coming soon<\/em>)<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-169 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/balance.png\" alt=\"\" width=\"201\" height=\"168\" \/><\/p>\n<p>XPR Mettle Toledo microbalance (readability: 0.5 \u03bcg)<\/p>\n<p>MT5 Mettle Toledo microbalance (readability: 1 \u03bcg)<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-large wp-image-329 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/03\/xrf-792x610.png\" alt=\"\" width=\"201\" height=\"154.8\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/xrf-792x610.png 792w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/xrf-396x305.png 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/xrf-768x591.png 768w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/xrf.png 877w\" sizes=\"(max-width: 792px) 100vw, 792px\" \/><\/p>\n<p>Bruker Nano S2 Picofox XRF<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-176 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/alpha.png\" alt=\"\" width=\"201\" height=\"173\" \/><\/p>\n<p>ORTEC alpha spectrometers<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #8b2a35\"><strong><u>Material Handling Apparatus:<\/u><\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-170 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/box1.png\" alt=\"\" width=\"180.4\" height=\"205\" \/><\/p>\n<p><span style=\"color: #8b2a35\"><strong><u><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-308\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/03\/Picture1-12-792x659.png\" alt=\"\" width=\"156.4\" height=\"130\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/Picture1-12-792x659.png 792w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/Picture1-12-396x330.png 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/Picture1-12-768x639.png 768w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/Picture1-12-990x824.png 990w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/03\/Picture1-12.png 1114w\" sizes=\"(max-width: 792px) 100vw, 792px\" \/><\/u><\/strong><\/span><\/p>\n<p>Inert-gas glovebox and radiological glovebox<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-153 alignleft\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/misco.png\" alt=\"\" width=\"173\" height=\"211.3\" \/><\/p>\n<p>Leica M80 stereomicroscope and Zoom 2000 stereomicroscopes<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p> <\/p>\n<h4>Laboratory:<\/h4>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-188\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-792x232.jpg\" alt=\"\" width=\"792\" height=\"232\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-792x232.jpg 792w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-396x116.jpg 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-768x225.jpg 768w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-990x290.jpg 990w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/A4A8D1F6-5C5F-478B-ACFB-9F02BB7E83FB-32285-0000226CFEB8858F_tmp-1188x347.jpg 1188w\" sizes=\"(max-width: 792px) 100vw, 792px\" \/><br \/> The Guo Labs are fully equipped with unique high-temperature calorimetry instruments, high-pressure apparatus, and a complete synthesis capability for material preparation.<\/p>\n<h4>Equipment:<\/h4>\n<p><strong>High-Temperature Calorimeters:<\/strong><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-134\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/Alexsys-396x311.png\" alt=\"\" width=\"350\" height=\"275\" srcset=\"https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/Alexsys-396x311.png 396w, https:\/\/wpcdn.web.wsu.edu\/wp-chem\/uploads\/sites\/1761\/2019\/01\/Alexsys.png 483w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/p>\n<p>Setaram AlexSYS-1000 Calvet-type calorimeter for solution and reaction calorimetry at 500 to 1000 \u00b0C<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-138\" src=\"https:\/\/s3.wp.wsu.edu\/uploads\/sites\/1761\/2019\/01\/Setsys1.png\" alt=\"\" width=\"172\" height=\"215\" \/> <img decoding=\"async\" loading=\"lazy\" ... <a href=\"https:\/\/chem.wsu.edu\/guo\/capabilities\/\" class=\"more-link\"\/><span class=\"more-default\">&raquo; More &#8230;<\/span><\/p>\n","protected":false},"author":5505,"featured_media":0,"parent":0,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"template-builder.php","meta":[],"wsuwp_university_location":[],"wsuwp_university_org":[],"_links":{"self":[{"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/pages\/84"}],"collection":[{"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/users\/5505"}],"replies":[{"embeddable":true,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/comments?post=84"}],"version-history":[{"count":58,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/pages\/84\/revisions"}],"predecessor-version":[{"id":396,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/pages\/84\/revisions\/396"}],"wp:attachment":[{"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/media?parent=84"}],"wp:term":[{"taxonomy":"wsuwp_university_location","embeddable":true,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/wsuwp_university_location?post=84"},{"taxonomy":"wsuwp_university_org","embeddable":true,"href":"https:\/\/chem.wsu.edu\/guo\/wp-json\/wp\/v2\/wsuwp_university_org?post=84"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}